Paper Title : Efficient use of steel fiber in high-strength reinforced concrete columns
Author Name : Zena R. Aljazaeri, Hussein K Al-Qabbani and Laith Khalid Al-Hadithy
Abstract :

The inclusion of steel fibers has been widely used in column members due to its effectiveness in enhancing strength, ductility, and delaying concrete cover spalling failure. Reinforced concrete columns are recently included steel fibers to enhance their structural performance and control the strain in concrete. In this study, partially-fibered and fully-fibered high-strength concrete (HSC) columns were investigated and compared to non-fibered HSC columns. The partially-fibered columns were examined here to eliminate the extra use of steel fibers through the confined core of the columns. The experimental work included different study parameters: percentage of steel fiber content, columns’ length, and internal reinforcement details. The columns were tested under concentric axial loads. The results were analyzed in terms of improvement in the ultimate load, displacement ductility, and energy absorption. The test results determined the impact of using steel fibers in enhancing the axial ultimate load capacities of HSC columns between 14% to 80% of that in non-fibered columns and controlling the concrete cover spalling failure. As well, the test results showed that the increase in steel fiber content improved both the ductility displacement index by 29% to 66% of that in the non-fibered column and the energy absorption index by 1.5 to 3.2 of that in the non-fibered column.

Keywords : Steel fiber, High-strength concrete, Columns, Axial compression, Ultimate load, Failure.
Cite this article : Aljazaeri ZR, Al-Qabbani HK, Al-Hadithy LK. Efficient use of steel fiber in high-strength reinforced concrete columns. International Journal of Advanced Technology and Engineering Exploration. 2022; 9(88):286-298. DOI:10.19101/IJATEE.2021.875201.
References :
[1]Ganesan N, Murthy JR. Strength and behavior of confined steel fiber reinforced concrete columns. Materials Journal. 1990; 87(3):221-7.
[Google Scholar]
[2]Jin L, Ding Z, Li D, Du X. Experimental and numerical investigations on the size effect of moderate high-strength reinforced concrete columns under small-eccentric compression. International Journal of Damage Mechanics. 2018; 27(5):657-85.
[Crossref] [Google Scholar]
[3]Hsu CT, Hsu LS, Tsao WH. Biaxially loaded slender high-strength reinforced concrete columns with and without steel fibres. Magazine of concrete Research. 1995; 47(173):299-310.
[Crossref] [Google Scholar]
[4]Foster SJ, Attard MM. Strength and ductility of fiber-reinforced high-strength concrete columns. Journal of Structural Engineering. 2001; 127(1):28-34.
[Crossref] [Google Scholar]
[5]Foster SJ. On behavior of high-strength concrete columns: cover spalling, steel fibers, and ductility. Structural Journal. 2001; 98(4):583-9.
[Google Scholar]
[6]Lima JHC, Giongo JS. Steel-fibre high-strength concrete prisms confined by rectangular ties under concentric compression. Materials and Structures. 2004; 37(10):689-97.
[Crossref] [Google Scholar]
[7]Liao WC, Perceka W, Liu EJ. Compressive stress-strain relationship of high strength steel fiber reinforced concrete. Journal of Advanced Concrete Technology. 2015; 13(8):379-92.
[Crossref] [Google Scholar]
[8]Tokgoz S. Effects of steel fiber addition on the behaviour of biaxially loaded high strength concrete columns. Materials and Structures. 2009; 42(8):1125-38.
[Crossref] [Google Scholar]
[9]Hadi MN. Reinforcing concrete columns with steel fibres. Asian Journal of Civil Engineering (Building and Housing). 2009; 10(1):79-95.
[Google Scholar]
[10]Paultre P, Eid R, Langlois Y, Lévesque Y. Behavior of steel fiber-reinforced high-strength concrete columns under uniaxial compression. Journal of Structural Engineering. 2010; 136(10):1225-35.
[Crossref] [Google Scholar]
[11]Mohammadi HM. Behaviour of high performance fibre reinforced concrete columns under axial loading (Doctoral dissertation, University of Ottawa). 2014.
[Google Scholar]
[12]Perceka W, Liao WC, Wang YD. High strength concrete columns under axial compression load: hybrid confinement efficiency of high strength transverse reinforcement and steel fibers. Materials. 2016; 9(4):1-25.
[Crossref] [Google Scholar]
[13]Balanji EK, Sheikh MN, Hadi MN. Performance of high strength concrete columns reinforced with hybrid steel fiber under different loading conditions. Proceedings of the first european and mediterranean structural engineering and construction conference 2016 (pp.35-40).
[Crossref] [Google Scholar]
[14]Hung CC, Hu FY. Behavior of high-strength concrete slender columns strengthened with steel fibers under concentric axial loading. Construction and Building Materials. 2018; 175:422-33.
[Crossref] [Google Scholar]
[15]Wu X, Kang TH, Mpalla IB, Kim CS. Axial load testing of hybrid concrete columns consisting of UHPFRC tube and normal-strength concrete core. International Journal of Concrete Structures and Materials. 2018; 12(1):1-13.
[Crossref] [Google Scholar]
[16]Al-taan SA, Aldoski AJ. Strength of steel fiber high-strength reinforced concrete columns under concentric and eccentric loads. Jordan Journal of Civil Engineering. 2020; 14(2):210-24.
[Google Scholar]
[17]Usman M, Farooq SH, Umair M, Hanif A. Axial compressive behavior of confined steel fiber reinforced high strength concrete. Construction and Building Materials. 2020.
[Crossref] [Google Scholar]
[18]Gorgis IN, Khalil WI, Mahdi ZR. Behavior of high performance fiber reinforced concrete columns: experimental investigation. Novel Perspectives of Engineering Research. 2021; 3:37-55.
[Crossref] [Google Scholar]
[19]Perceka W, Liao WC. Experimental study of shear behavior of high strength steel fiber reinforced concrete columns. Engineering Structures. 2021.
[Crossref] [Google Scholar]
[20]Suda VR, Rao PS. Experimental studies on steel fiber reinforced short ternary columns under axial loading. Materials Today: Proceedings. 2021; 38:2975-80.
[Crossref] [Google Scholar]
[21]Altun F, Haktanir T, Ari K. Effects of steel fiber addition on mechanical properties of concrete and RC beams. Construction and Building Materials. 2007; 21(3):654-61.
[Crossref] [Google Scholar]
[22]Behbahani HP, Nematollahi B, Farasatpour M. Steel fiber reinforced concrete: a review. International conference on structural engineering construction and management 2011.
[Google Scholar]
[23]American society for testing and materials. ASTM A370: standard test methods and definitions for mechanical testing of steel products. West Conshohocken: ASTM.2014.
[Google Scholar]
[24]American society for testing and materials. ASTM A370: standard test methods and definitions for mechanical testing of steel products. West Conshohocken: ASTM. 2014.
[Google Scholar]
[25]ASTM International committee C09 on concrete and concrete aggregates. Standard test method for splitting tensile strength of cylindrical concrete specimens1. ASTM International; 2017.
[Google Scholar]